<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>System Sensor &#8211; EcoSmart Security</title>
	<atom:link href="https://ecosmartsecurity.com/shop/brands/system-sensor/feed/" rel="self" type="application/rss+xml" />
	<link>https://ecosmartsecurity.com</link>
	<description></description>
	<lastBuildDate>Tue, 29 Sep 2026 14:43:02 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.2</generator>
	<item>
		<title>System Sensor COSMOD4W 4-Wire Smoke/CO Interface Module</title>
		<link>https://ecosmartsecurity.com/shop/accessories/security-system-accessories/security-interface-modules/system-sensor-cosmod4w-4-wire-smoke-co-interface-module/</link>
		
		<dc:creator><![CDATA[admin@keypermarketing.com]]></dc:creator>
		<pubDate>Wed, 15 Jul 2026 16:38:29 +0000</pubDate>
				<guid isPermaLink="false">https://prestonh20.sg-host.com/?post_type=product&#038;p=1615</guid>

					<description><![CDATA[Connect up to 12 compatible COSMO-4W or 4WTA-B detectors to a compatible alarm panel with separate smoke and CO zones and synchronized alarm sounders.]]></description>
										<content:encoded><![CDATA[<p>The System Sensor COSMOD4W interfaces compatible four-wire COSMO-4W combination smoke/CO detectors with an alarm control panel. Up to 12 compatible COSMO-4W and/or 4WTA-B detectors can share the module, which separates smoke and carbon monoxide events into distinct panel zones for clearer monitoring and response.</p>
<p>The module interconnects detector sounders and supports synchronized Temporal 3 smoke and Temporal 4 carbon monoxide patterns. Dedicated smoke, CO, loop-status, and trouble indications make testing and service easier, while trigger inputs allow compatible panel outputs to coordinate alarms across the connected detector circuit.</p>
<p>As part of a complete smoke and <a href="https://www.alliedhomesecurity.net/security-equipment/carbon-monoxide-detector/">carbon monoxide detection</a> plan, Please verify resettable power, detector compatibility, EOL relay wiring, trigger behavior, panel zones, and local code requirements.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>System Sensor COSMOD2W 2-Wire Smoke/CO Interface Module</title>
		<link>https://ecosmartsecurity.com/shop/accessories/security-system-accessories/security-interface-modules/system-sensor-cosmod2w-2-wire-smoke-co-interface-module/</link>
		
		<dc:creator><![CDATA[admin@keypermarketing.com]]></dc:creator>
		<pubDate>Wed, 15 Jul 2026 16:38:07 +0000</pubDate>
				<guid isPermaLink="false">https://prestonh20.sg-host.com/?post_type=product&#038;p=1609</guid>

					<description><![CDATA[Connect up to 12 compatible COSMO-2W or 2WTA-B detectors to a compatible panel with separate smoke and CO reporting, maintenance signaling, and EZ Walk testing.]]></description>
										<content:encoded><![CDATA[<p>The System Sensor COSMOD2W is the required two-wire interface between compatible COSMO-2W combination detectors and an alarm panel. It supports up to 12 compatible COSMO-2W and/or 2WTA-B detectors, translating loop activity into distinct smoke and carbon monoxide alarm zones instead of treating every event as one generic condition.</p>
<p>The module also reports loop faults, smoke-maintenance needs, CO trouble and end-of-life conditions, and freeze trouble from compatible detectors. EZ Walk testing helps verify loop communication, while synchronized Temporal 3 smoke and Temporal 4 CO sounder control gives occupants a clearer audible distinction between alarm types.</p>
<p>In a professionally monitored <a href="https://www.alliedhomesecurity.net/security-equipment/smoke-detector/">smoke detection system</a>, Recommend confirming panel compatibility, detector count, loop resistance, EOL requirements, trigger programming, and code-compliant placement before commissioning.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>System Sensor 5602 194 F Fixed/Rate-of-Rise Heat Detector</title>
		<link>https://ecosmartsecurity.com/shop/alarms-and-sensors/security-sensors/life-safety-sensors/system-sensor-5602-194-f-fixed-rate-of-rise-heat-detector/</link>
		
		<dc:creator><![CDATA[admin@keypermarketing.com]]></dc:creator>
		<pubDate>Wed, 15 Jul 2026 15:51:34 +0000</pubDate>
				<guid isPermaLink="false">https://prestonh20.sg-host.com/?post_type=product&#038;p=1557</guid>

					<description><![CDATA[Protect higher-temperature spaces with a 194 F fixed threshold, restorable 15 F-per-minute rate-of-rise response, and single-circuit mechanical design.]]></description>
										<content:encoded><![CDATA[<p>The System Sensor 5602 is the high-temperature fixed/rate-of-rise model in the 5600 mechanical heat-detector family. Its fixed element activates at 194 F, while the restorable rate-of-rise section responds to a rapid temperature increase of approximately 15 F per minute.</p>
<p>That higher fixed threshold makes the 5602 useful in property-protection locations that normally run warmer than living or office spaces and where a smoke detector would be unsuitable. Exterior lettering identifies the temperature and activation method, and the external collector drops after an alarm so a technician can quickly locate the operated device.</p>
<p>The detector supports several common back boxes through its reversible bracket and uses straightforward 14-22 AWG terminal screws. <em>Allied selects the model only after reviewing the normal ambient temperature, ceiling conditions, listed spacing reductions, and local requirements.</em></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>System Sensor 5601P 135 F Fixed/Rate-of-Rise Heat Detector</title>
		<link>https://ecosmartsecurity.com/shop/alarms-and-sensors/security-sensors/life-safety-sensors/system-sensor-5601p-135-f-fixed-rate-of-rise-heat-detector/</link>
		
		<dc:creator><![CDATA[admin@keypermarketing.com]]></dc:creator>
		<pubDate>Wed, 15 Jul 2026 15:51:15 +0000</pubDate>
				<guid isPermaLink="false">https://prestonh20.sg-host.com/?post_type=product&#038;p=1552</guid>

					<description><![CDATA[Use mechanical heat detection where smoke sensing is unsuitable with a 135 F fixed threshold, restorable 15 F-per-minute rate-of-rise element, and 50 x 50 ft listed spacing.]]></description>
										<content:encoded><![CDATA[<p>The System Sensor 5601P is a single-circuit mechanical heat detector for property-protection applications where dust, vapor, or normal airborne particles make a smoke detector inappropriate. It responds either when the fixed element reaches 135 F or when temperature rises approximately 15 F in one minute.</p>
<p>The rate-of-rise portion is restorable for field testing, while the fixed-temperature element is not. A dropped external collector makes an activated detector easier to identify during inspection. The plain white housing suits residential and light-commercial interiors, and a reversible bracket supports common single-gang, octagonal, and square back-box arrangements.</p>
<p><strong>This detector is intended for property protection and is not a substitute for required life-safety smoke detection.</strong> Allied applies the listed spacing only after accounting for ceiling height, room conditions, local code, and the authority having jurisdiction. <em>The normally open circuit and every detector location are tested before monitoring is activated.</em></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>System Sensor COSMO-4W i4 4-Wire Smoke and CO Detector</title>
		<link>https://ecosmartsecurity.com/shop/alarms-and-sensors/security-sensors/life-safety-sensors/smoke-detectors/system-sensor-cosmo-4w-i4-4-wire-smoke-and-co-detector/</link>
		
		<dc:creator><![CDATA[admin@keypermarketing.com]]></dc:creator>
		<pubDate>Wed, 15 Jul 2026 15:50:33 +0000</pubDate>
				<guid isPermaLink="false">https://prestonh20.sg-host.com/?post_type=product&#038;p=1544</guid>

					<description><![CDATA[Combine four-wire smoke and CO sensing, distinct system signals, RealTest verification, a replaceable CO cell, and temporal-three/four sounder tones.]]></description>
										<content:encoded><![CDATA[<p>The System Sensor COSMO-4W gives a compatible four-wire fire and life-safety circuit separate photoelectric smoke and electrochemical CO detection in one enclosure. The required COSMOD4W interface translates those events into distinct smoke and carbon-monoxide zones and can interconnect compatible detector sounders across the module.</p>
<p>Red and blue LEDs make the active hazard easy to identify. Smoke produces a temporal-three pattern, CO produces temporal four, and the integral 85 dBA sounder supplements the property&#8217;s listed notification appliances. Technicians can use RealTest canned-CO testing to exercise the actual gas cell, and the electrochemical module can be replaced at its typical ten-year end of life without discarding the complete detector.</p>
<p>A four-wire combination detector can be valuable when a property already has separate detector power and alarm conductors. We Recommend evaluating that wiring as part of the whole <a href="https://www.alliedhomesecurity.net/home-security-systems/">home security and life-safety system</a>, then verify interface status, smoke and CO reporting, sounder behavior, reset, and monitoring response.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>System Sensor 4WTA-B i3 4-Wire Smoke and Heat Detector with Sounder</title>
		<link>https://ecosmartsecurity.com/shop/alarms-and-sensors/security-sensors/life-safety-sensors/smoke-detectors/system-sensor-4wta-b-i3-4-wire-smoke-and-heat-detector-with-sounder/</link>
		
		<dc:creator><![CDATA[admin@keypermarketing.com]]></dc:creator>
		<pubDate>Wed, 15 Jul 2026 15:50:11 +0000</pubDate>
				<guid isPermaLink="false">https://prestonh20.sg-host.com/?post_type=product&#038;p=1539</guid>

					<description><![CDATA[Equip a compatible four-wire circuit with photoelectric smoke sensing, a 135 F thermal element, freeze trouble, and an 85 dB temporal sounder.]]></description>
										<content:encoded><![CDATA[<p>The System Sensor 4WTA-B combines smoke, fixed-temperature heat, freeze monitoring, and local audible warning in a conventional four-wire detector. Separate power and alarm paths make it appropriate only for panels and circuits designed to supervise and reset four-wire fire devices.</p>
<p>Its photoelectric chamber uses drift compensation and smoothing to maintain useful sensitivity as environmental conditions change. A restorable 135 F thermal element adds heat response, the red LED identifies a freeze-trouble condition below 41 F, and the built-in horn produces an 85 dBA temporal-three pattern during alarm.</p>
<p>When a system requires multiple i3 sounders to operate together, a compatible reversing and synchronization module is part of the design rather than an optional afterthought.</p>
<p><strong>Test detector power, alarm contacts, end-of-line supervision, synchronized output, panel reset, and monitoring transmission together.</strong> This keeps the installation understandable for the customer and serviceable later.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>System Sensor 4W-B i3 4-Wire Photoelectric Smoke Detector</title>
		<link>https://ecosmartsecurity.com/shop/alarms-and-sensors/security-sensors/life-safety-sensors/smoke-detectors/system-sensor-4w-b-i3-4-wire-photoelectric-smoke-detector/</link>
		
		<dc:creator><![CDATA[admin@keypermarketing.com]]></dc:creator>
		<pubDate>Wed, 15 Jul 2026 15:49:53 +0000</pubDate>
				<guid isPermaLink="false">https://prestonh20.sg-host.com/?post_type=product&#038;p=1536</guid>

					<description><![CDATA[Use separate power and alarm wiring with a 4-wire photoelectric smoke detector, drift compensation, removable chamber, and dual-color status LEDs.]]></description>
										<content:encoded><![CDATA[<p>The System Sensor 4W-B is the four-wire version of the i3 photoelectric detector, separating detector power from the alarm contacts used by the control panel. That architecture can suit existing four-wire fire zones and retrofit layouts where a compatible end-of-line power-supervision relay is part of the design.</p>
<p>The detector automatically compensates for gradual contamination in the optical chamber and uses smoothing algorithms to reject short disturbances. Its removable cover and chamber support scheduled cleaning, while the red and green LEDs make standby, out-of-sensitivity, and alarm conditions visible from the floor.</p>
<p>A pre-wired plug-in base helps service work stay orderly, but the circuit still needs a correct power-reset method and supervision arrangement. In an <a href="https://www.alliedhomesecurity.net/existing-systems/">existing alarm system takeover</a>, verify every conductor and end-of-line device before deciding whether a 4W-B is a compatible replacement. <em>The completed zone is smoke-tested and confirmed at the panel and monitoring station.</em></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>System Sensor COSMO-2W i4 2-Wire Smoke and CO Detector</title>
		<link>https://ecosmartsecurity.com/shop/alarms-and-sensors/security-sensors/life-safety-sensors/smoke-detectors/system-sensor-cosmo-2w-i4-2-wire-smoke-and-co-detector/</link>
		
		<dc:creator><![CDATA[admin@keypermarketing.com]]></dc:creator>
		<pubDate>Wed, 15 Jul 2026 15:49:32 +0000</pubDate>
				<guid isPermaLink="false">https://prestonh20.sg-host.com/?post_type=product&#038;p=1530</guid>

					<description><![CDATA[Monitor smoke and carbon monoxide with a 2-wire system detector, replaceable 10-year CO cell, RealTest, distinct panel signals, and 85 dB sounder.]]></description>
										<content:encoded><![CDATA[<p>The System Sensor COSMO-2W combines a photoelectric smoke chamber and electrochemical carbon-monoxide cell in one system-connected detector. Used with the required COSMOD2W interface, it sends distinct smoke, CO, and optional trouble information to a compatible alarm panel instead of reducing both hazards to one generic zone.</p>
<p>Smoke events use a temporal-three tone and red LED; carbon-monoxide events use temporal four and a blue LED. RealTest allows a technician to verify that canned CO reaches and activates the sensing cell, while the field-replaceable CO module carries a typical ten-year end-of-life timer. Drift compensation and smoothing algorithms support stable smoke sensitivity, and the two-wire loop can use EZ Walk verification.</p>
<p>For homes and small businesses, one coordinated detector can reduce wall and ceiling clutter while preserving the correct monitored response for each hazard. It is Recommended to verify the interface-module capacity, listed panel connection, detector spacing, sounder behavior, and central-station signals before placing the zone in service.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>System Sensor 2WTA-B i3 2-Wire Smoke and Heat Detector with Sounder</title>
		<link>https://ecosmartsecurity.com/shop/alarms-and-sensors/security-sensors/life-safety-sensors/smoke-detectors/system-sensor-2wta-b-i3-2-wire-smoke-and-heat-detector-with-sounder/</link>
		
		<dc:creator><![CDATA[admin@keypermarketing.com]]></dc:creator>
		<pubDate>Wed, 15 Jul 2026 15:49:07 +0000</pubDate>
				<guid isPermaLink="false">https://prestonh20.sg-host.com/?post_type=product&#038;p=1523</guid>

					<description><![CDATA[Combine photoelectric smoke sensing, 135 F heat detection, freeze trouble, and an 85 dB temporal sounder on a compatible two-wire circuit.]]></description>
										<content:encoded><![CDATA[<p>The System Sensor 2WTA-B adds more local warning capability to a conventional two-wire fire loop. Its photoelectric chamber evaluates smoke, a restorable 135 F thermal element provides a second detection method, and the detector can signal a freeze-trouble condition when the surrounding temperature falls below 41 F.</p>
<p>An integral piezoelectric horn produces an 85 dBA temporal-three pattern during smoke alarm operation. With the proper reversing relay, compatible heads on the loop can sound together and remain synchronized. Drift compensation, smoothing algorithms, remote maintenance reporting, and the two-wire EZ Walk test help the service technician identify circuit and sensitivity issues without treating every visit as a blind search.</p>
<p><strong>Panel compatibility and notification design must be verified before this detector is installed.</strong></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>System Sensor 2W-B i3 2-Wire Photoelectric Smoke Detector</title>
		<link>https://ecosmartsecurity.com/shop/alarms-and-sensors/security-sensors/life-safety-sensors/smoke-detectors/system-sensor-2w-b-i3-2-wire-photoelectric-smoke-detector/</link>
		
		<dc:creator><![CDATA[admin@keypermarketing.com]]></dc:creator>
		<pubDate>Wed, 15 Jul 2026 15:48:38 +0000</pubDate>
				<guid isPermaLink="false">https://prestonh20.sg-host.com/?post_type=product&#038;p=1516</guid>

					<description><![CDATA[Add system-connected smoke detection with a 2-wire photoelectric head, drift compensation, dual-color status LEDs, and plug-in mounting base.]]></description>
										<content:encoded><![CDATA[<p>The System Sensor 2W-B is a conventional two-wire photoelectric smoke detector for compatible listed alarm panels. Its sensing chamber and microprocessor are designed to recognize smoke while compensating for gradual dust buildup, helping the detector remain within its intended sensitivity range between scheduled service visits.</p>
<p>A pre-wirable base, inline terminals, broad back-box support, and Stop-Drop &#8216;N Lock head make installation and replacement more orderly. Green and red LEDs communicate standby, alarm, and maintenance conditions at a glance; with an i3-ready panel or 2W-MOD2, the detector can also report maintenance needs and participate in EZ Walk loop verification.</p>
<p>This is a system detector, not a standalone household alarm.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
